Details


.jpg)



Specifications
|
test accuracy |
±O.5degree |
|
Temperature measurement range |
-150℃~1300℃ degree |
|
Thermocouple type |
Ktype |
|
Data transmission method |
USBtransmission |
|
Measurement channel |
6channel |
|
Data storage |
Can be stored at once16piece of data,Equipped with storage and busy recording function |
|
Test Type |
Both chain and track modes can be tested |
|
data analysis |
Can automatically read data and determine whether the furnace temperature curve is qualified |
feature
● High efficiency, continuous storage of data16At the same time, download it to the computer for group analysis and processing;
Adopting a modular analysis mode, the system is simple and fast to analyze, and can be based onPC(Windows)AndPDA
(Pocket)Conduct data analysis;
Low power consumption, powered by lithium batteries, continuous use for up to100 About an hour, fast charging10 minute
Ready to use;
The communication mode adopts serial portUSBAnd wireless transmission, suitable for multiple working environments and application fields with multiple layers
Thermal insulation protection, made of refined stainless steel, can cope with the strictest lead-free processes and withstand harsh industrial conditions
environment
● Rigorous process manufacturing and accurate calibration services, all calibrations are carried out usingFLUKE-724Correction, with the middle
The largest countryCTICalibration agency partners ensure that each machine is accurate, reliable, small in size, and has a large storage capacity
(2,000,000Data points), usingFLASHStorage chip, no unexpected loss of data;
advantage
● Easy and convenient operation, all data is managed in a database, and can be quickly imported into the process using a wizard
analysis;
Software operation is equipped with language versions such as Simplified Chinese, Traditional Chinese, English, Korean, Japanese, etc;
High temperature protection, the internal temperature of the instrument exceeds70The test function automatically shuts down at ℃, exceeding the limit80Automatic power off at ℃
Source;
● Sampling frequency setting(0.1 Seconds~30 Minutes);
Measurement accuracy ±0.5℃(-150℃~1300℃), the collection method can be selected as button start or temperature trigger
Start or time start;
● Intelligent control, with indicator lights indicating low battery level, charging status, data download, etc. in any situation
Data clearing, memory overflow, high temperature warning, instrument reset, etc;
Technical Specifications
memoryMemory 2 ,000,000 points
test channelTest Channel 6channel
sampling frequencySampling frequency 0.1s~ 30 Min
precisionPrecisionscholar0.5C
resolutionResolution 0.1C
Working VoltageRun Voltage DC3.7V~DC4.2V
batteryBatter 1000mAh
Thermocouple typeThermocouple Types Ktype
Instrument power consumptionPower≤10mAh
Maximum internal operating temperatureMax. inner runtemperature 70'C
Simulation function:optionalsimulation fuction: option
software analysis
●TTS-A60TThe furnace temperature testing and analysis software involves a wide range of temperature testing fields in the electronic assembly process,
It is an efficient, convenient, fast, and easy to operate analysis software, and its modular structure enables customers to
You can freely choose according to your own needs. The analysis functions of this software are as follows:
Record the temperature of each point and reflect it through a curve
The change in slope and time between any two points
● Changes in slope and time above or below any temperature point
Accurately reflect the highest, lowest, average temperature, and standard deviation
● It can also set alarms for various parts and provide a detailed analysis process for wave soldering
Configuration List
nameItemquantity/ Qty
packing boxPackage box 1
hostHost 1
Insulation boxInsulation heat box 1
Instruction ManualUser Manual 1
softwareSoftware CD 1
data cableData cable 1
thermocoupleThermocouple plugRandom allocationAttachment
chargerCharger 1
Inspection CertificateQuality certification 1